• This email address is being protected from spambots. You need JavaScript enabled to view it.
  • Sun - Fri 8:00 - 20:30
PVi® Receives FDA Clearance
Pin It

Masimo today announced that PVi® has received FDA clearance as a continuous, noninvasive, dynamic indicator of fluid responsiveness in select populations of mechanically ventilated adult patients.

PVi, or pleth variability index, is a measure of the dynamic changes in perfusion index that occur during the respiratory cycle.

William C. Wilson, MD, MA, Chief Medical Officer at UCI Health, said, “Anesthesiologists and critical care physicians have long recognized the importance of dynamic measures of intravascular volume and fluid responsiveness. Previously this data could only be acquired using an invasive arterial line, and/or additional sophisticated devices. With the Masimo pleth variability index (PVi), one can now obtain this essential data using the pulse oximeter probe and following the continuous readout on the monitor. The PVi technology has undergone rigorous peer-reviewed evaluation, and demonstrated efficacy in determining adequacy of intravascular volume for guiding goal-directed therapy. The recent clearance of the Masimo PVi system will serve as another major breakthrough in promoting patient safety.”

Available alongside Masimo SET® pulse oximetry and rainbow® Pulse CO-Oximetry on a variety of 2-LED, 4-LED, and 8-LED Masimo sensors, PVi is an index between 0 and 100 that is calculated using a proprietary algorithm based upon the relative variability of the pleth waveform.

Hospital protocols such as Enhanced Recovery After Surgery (ERAS) and Goal-directed Therapy (GDT) recommend fluid management as part of larger initiatives designed to improve patient care and safety. Fluid management protocols look to balance fluids by identifying when patients may be fluid responsive. The utility of PVi as a fluid responsiveness indicator has been demonstrated in more than 100 independent, published studies, including in ERAS and GDT protocols.1 For example:

    ERAS: In a study of 109 patients undergoing colorectal surgery, researchers found that the implementation of an ERAS protocol which included PVi led to substantial reductions in lengths of stay (from a median of 5 days to 3 days), complication rates (from 30.1% to 14.7%), and costs per patient (from mean cost at 30 days of $20,435 to $13,306 per patient)—in addition to improved patient satisfaction.2
    GDT: In a study of 82 patients undergoing major abdominal surgery, researchers found that GDT with fluid management using PVi reduced the volume of intraoperative fluid infused and reduced intraoperative and postoperative lactate levels.3

In addition, PVi has been used in combination with Masimo’s noninvasive, continuous hemoglobin monitoring technology (SpHb®). In a study published last year involving 18,716 surgical patients at a hospital in Limoges, France, researchers investigated the effects of implementing a hospital-wide protocol for fluid management and blood administration using PVi and SpHb. The researchers found that use of an integrated GDT algorithm using both PVi and SpHb led to earlier transfusion and fewer units of blood transfused, as well as a 33% lower mortality rate 30 days after surgery and a 29% lower mortality rate 90 days after surgery. A year after the study ended, when the hospital did not use PVi and SpHb technology, the mortality rate returned to levels similar to those found before implementation of the GDT protocol.4

Stephen Weston, MD, Health Sciences Associate Clinical Professor and Medical Director, Operating Room Support Services, Department of Anesthesia and Perioperative Care at the University of California, San Francisco, said, “At UCSF we display PVi on all of our Masimo pulse oximeters. PVi is a great tool for helping to assess the patient’s fluid status. Having a fluid responsiveness monitor incorporated into something as ubiquitous as pulse oximetry allows us to monitor fluid responsiveness universally. I integrate PVi into my routine sweeps of the hemodynamic data in the operating room, and we’ve rolled out this functionality to the intensive care units as well. Without PVi, I feel that I’m flying a little bit blind.”

Joe Kiani, Founder and CEO of Masimo, said, “We are thrilled that at long last we are able to offer clinicians and patients in the U.S. the full benefits of PVi monitoring. Multiple studies have shown how this breakthrough noninvasive indicator of fluid responsiveness can help improve outcomes and reduce costs on mechanically ventilated patients – with no more equipment needed than a software upgrade with most existing Masimo SET® and rainbow® platforms and the existing Masimo SET® sensors that so many top hospitals around the world already use for pulse oximetry.”

Company Name: Masimo
About Company: Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes and reduce the cost of care.
Person of Contact: Evan Lamb
Phone: 949-396-3376